Ionizing bar EI Ex T & RI Ex O/M/V

Units for areas with potentially explosive atmospheres (ex zone)

For many years, HAUG has been a competent manufacturer of ionizing units approved for equipment in areas with potentially explosive atmospheres. These are intended to eliminate unwanted electrostatic charges in areas where hazardous gases may form, such as paint plants or printing machines.

Branches

  • Graphic industry: Screen, tampon and offset printing machines etc.
  • Paint shops: automotive paint applications, painting of plastic parts, etc.

Ionizing bar EI Ex T

The design of the ionizing bar EI Ex T complies with the European ATEX directivities. In combination with the power pack EN 92 Ex or Multistat Ex, it is suitable for use in manufacturing locations with potentially explosive atmospheres resulting from gases of explosion group IIA, temperature classes T4 to T6.

Technical data EI Ex T

Types EI Ex T for connection to Multistat Ex Order-No.: 03.8051.000
EI Ex T for connection to EN 92 Ex Order-No.: 03.8251.000

Subject to technical changes!

Accessories EI Ex T

By installing the ionizing bar in a suitable body, a compressed-air assisted ionization system can be created. This air gate is particularly suitable for blowing-off processes on plate and web material or where installation is difficult, e.g. in the case of distances further away from the material.

Four basic body types LS Ex, KL Ex, KM Ex and AK Ex are available. Air consumption figures on request.

Technical illustration EI EX T



 

Ring ionizers RI Ex O/M/V

The ring ionizers RI EX O/M/V are supplied as a hand-held unit (RI Ex M/V) with compressed air gun, or for fixed installation (RI Ex O).

Due to their compressed-air assistance, these units are ideally suited to blowing off workpiece surfaces using ionized air. At the same time, electric charges on non-conductive materials can be eliminated in one process.

In combination with power pack EN 92 Ex or Multistat Ex, the units are suitable for use in manufacturing locations with potentially explosice atmospheres resulting from gases of explosion group IIA, temperature class T4 to T6.

Air consumption figures are dependent on the pressure and available on request.

Technical data RI Ex O/M/V

Types RI Ex O
(without air gun)
for connection to Multistat Ex
for connection to EN 92 Ex
Order-No.: 04.7190.000
Order-No.: 04.7290.000
RI Ex M
(with air gun, without protection hose)
for connection to Multistat Ex
for connection to EN 92 Ex
Order-No.: 04.7191.000
Order-No.: 04.7291.000
RI Ex V
(reinforced, with air gun, with protection hose)
for connection to Multistat Ex
for connection to EN 92 Ex
Order-No.: 04.7192.000
Order-No.: 04.7292.000

Subject to technical changes!

Accessories RI EX O/M/V

Standard bar holder for RI Ex O Order-No.: 10.7206.000
Filter control valve with pressure gauge incl. oil and water separator Order-No.: 11.7210.001
Air hose, fabric reinforced Ø 12 x 6 mm (external/internal), silicone-free Order-No.: X-6615
Protection hose for HV-cable Order-No.: X-6597


Technical illustration RI EX M