Needle ionizer NI

Special features and advantages

  • The equipment is supplied with a suction chamber, which permits particles escaping from a hollow body (bottle) to be sucked up.
  • This suction chamber can be unscrewed if the needle ionizer is operated without the suction facility.
  • The injection electrode can be exchanged! Please pay particular attention to this feature, as it permits the diameter and length of the injection electrode to be adapted to the particular hollow body (e.g. height of bottle and diameter).

Technical data

Types NI
einschl. 2 m HV-cable and injection electrode (Ø 6 or 8 mm, up to a Length of 50 mm)
Order-No.: 14.7521.000
NI
without Kabel, cable length on request
Order-No.: 04.7521.000
Injection electrode Ø 6 mm,
Length up to 50 mm
Order-No.: 06.7521.000
Ø 8 mm,
Length up to 50 mm
Order-No.: 06.7522.000
Further lengths on request.
Operating temperature +5 °C to +45 °C
Storage/transport temperature -15 °C to +60 °C
Smallest bending radius (cable) R 50

Subject to technical changes!

Suitable Power packs

Connectable lengths
(ionizing unit incl.
high-voltage cable)
EN SL max. 5 m
EN SL LC / EN SL RLC max. 10 m
EN 8 / EN 8 LC max. 18 m
Multistat max. 18 m
EN 70 / EN 70 LC max. 2 x 18 m


Technical illustration