Power pack Multistat Plus

The high-voltage power pack Multitstat Plus with its long permissible connected length and extended monitoring facilities is a high-performance unit. The Multistat Plus is particularly suited to systems with multiple ionizing bars. The extended functions of the Multistat Plus allow improved monitoring of the ionizing system set-up with this unit.

The unit has 6 individually monitored high-voltage sockets. Any overload is indicated by means of a warning lamp and a signal at the signalling socket.

All HAUG ionizing units can be connected using the X-2000 high-voltage connector system. The most appropriate HAUG ionizing units can therefore be used depending on the fitting dimensions, the required output and the application conditions.

Control

Overload lamp: indicates an overload at the HV connections.
Reset: in the event of failure, the unit will switch off – restart using Reset.
HV kV /
HV mA:
voltage of current indication on display.


Display

The display indicates the high-voltage or currents at the 6 high-voltage connections. The currents are output one after another in a fixed sequence. This allows good monitoring of the ionizing units connected to the HV sockets.

Technical data

Types Multistat Plus 115V
230V
Order-No.: 01.7863.100
Order-No.: 01.7862.100
Protection type IP 54
Protection class I
Supply voltage 115 VAC / 230 VAC (50 – 60 Hz)
Power consumption approx. 200 VA
Output-voltage approx. 6 – 8 kVAC
Output short-circuit current
per HV-Socket
(lk) ≤ 4 mA
(permissible operating range)
Load rating of signalling contacts: 24 VAC / 35 VDC max. 50mA
HV-terminals 6
Connectable length max. 6 x 10m (ionizing unit incl. HV-cable)
Operating temperature +5 °C to +45 °C
Storage/transport temperature -15 °C to +60 °C
Weight approx. 11 kg
Mains cable 2.6 m; fixed to the device

Subject to technical changes!

Accessories

Signalling cable K1
shielded,
incl. round plug
  5 m Order-No.: 06.8941.000
10 m Order-No.: 06.8941.001
20 m Order-No.: 06.8941.002
Round plug   Order-No.: X-0616
Angled plug   Order-No.: X-5718


Contact assignment signalling socket

Pin1 Signal output overload.
In the event of overload, a signal (approx. 12 V) is output.
Pin2 Signal output, voltage values for current monitoring of HV sockets.
Pin3 Input reset signal. After the unit has switched off following an overload, it can be restarted by means of this input.
Pin4 Signal ground GND
Pin5 Floating contact. Contact closed when high voltage is correct.
Pin6 Floating contact. Contact closed when high voltage is correct.
PinPE Ground


Technical illustration